configure sys-recovery-level

configure sys-recovery-level [all | none]

Description

Configures a recovery option for instances where a software exception occurs in ExtremeXOS.

Syntax Description

all Configures ExtremeXOS to log an error into the syslog and reboot the system after any software task exception occurs.
none
Configures the recovery level to none. No action is taken when a software task exception occurs; there is no system reboot, which can cause unexpected switch behavior.
Note: Use this parameter only under the guidance of Extreme Networks Technical Support personnel.

Default

The default setting is all.

Usage Guidelines

If the software fails, the switch automatically reboots or leaves the system in its current state. You must specify one of the following parameters for the system to respond to software failures:
  • all—The system will send error messages to the Syslog and reboot if any software task exception occurs.

  • none—No action is taken when a software task exception occurs. The system does not reboot, which can cause unexpected switch behavior.
    Note

    Note

    Use the none parameter only under the guidance of Extreme Networks Technical Support personnel.

The default setting and behavior is all. Extreme Networks strongly recommends using the default setting.

Displaying the System Recovery Setting

To display the software recovery setting on the switch, use the following command:

# show switch

This command displays general switch information, including the software recovery level. The following truncated output from an ExtremeSwitching switch displays the software recovery setting (displayed as Recovery Mode):

SysName:          TechPubs Lab
SysLocation:
SysContact:       support@extremenetworks.com, +1 888 257 3000
System MAC:       00:04:96:20:B4:13
SysHealth check:  Enabled (Normal)
Recovery Mode:    All
System Watchdog:  Enabled
Note

Note

All platforms display the software recovery setting as Recovery Mode.

Example

The following command configures a switch to not take an action when any software task exception occurs:

# configure sys-recovery-level none

History

This command was first available in ExtremeXOS 11.0.

Platform Availability

This command is available on all Universal switches supported in this document.